| 注册
首页|期刊导航|核安全|核级碳钢小径薄壁管冷弯拉伸试验不合格原因分析与质量控制措施

核级碳钢小径薄壁管冷弯拉伸试验不合格原因分析与质量控制措施

贺振宇 张强升 张发云 熊冬庆 邓冬

核安全2018,Vol.17Issue(1):83-86,4.
核安全2018,Vol.17Issue(1):83-86,4.

核级碳钢小径薄壁管冷弯拉伸试验不合格原因分析与质量控制措施

Failure Analysis and Quality Control Measures for the Cold Bending Tensile Test of Thin Wallpipe of Nuclear Grade Carbon Steel

贺振宇 1张强升 1张发云 1熊冬庆 1邓冬1

作者信息

  • 1. 环境保护部核与辐射安全中心,北京 100082
  • 折叠

摘要

Abstract

Thetension test resultof thin-walled tube after cold bendingis unqualified. Through the analysis of causes of tension test resultdata, includingraw material, cold bending, thickness and shape, measuring method and processing technical of test sample, confirm the reasonwhichthe tension test resultdata isunqualified. and re-tension test tothecold bending, adopt quality control measurefurther, ensured the tension test toachieve the requirementof standard.

关键词

小径试验/原因分析/质量控制措施

Key words

thin-walled tube/tensile test/causal analysis/quality control measures

分类

矿业与冶金

引用本文复制引用

贺振宇,张强升,张发云,熊冬庆,邓冬..核级碳钢小径薄壁管冷弯拉伸试验不合格原因分析与质量控制措施[J].核安全,2018,17(1):83-86,4.

核安全

1672-5360

访问量4
|
下载量0
段落导航相关论文