航天器环境工程2018,Vol.35Issue(3):277-282,6.DOI:10.3969/j.issn.1673-1379.2018.03.013
通信卫星真空热试验测试电缆集中控温方法
Method for centralized temperature control of testing cables in thermal vacuum test for communication satellite
摘要
Abstract
In the thermal vacuum test, a large number of cables are connected to the communication satellite through a flange outside the space environmental simulator. A part of the cables would work beyond the normal temperature range, which may lead to undesirable phase jumps. To solve this problem, a new type of cables temperature control device is proposed. With it, the centralized temperature control of the cables in complex vacuum cryogenic environment is realized. In the thermal vacuum test of a new-generation communications satellite, the temperature of the related cables is controlled within a range of 40 ℃±5 ℃, and the temperature difference of a single cable along its path is kept within ±3 ℃. Under the controlled temperature, the requirements of timing and phase of the satellite payload is guaranteed, and therefore the accuracy of the ground testing is also improved.关键词
航天器/真空热试验/测试电缆/真空低温环境/集中控温Key words
spacecrafts/thermal vacuum test/testing cables/vacuum cryogenic environment/centralized temperature control分类
航空航天引用本文复制引用
简亚彬,毕研强,周艳,吴越,杜春林..通信卫星真空热试验测试电缆集中控温方法[J].航天器环境工程,2018,35(3):277-282,6.基金项目
国家自然科学基金项目(编号:51506009) (编号:51506009)