剪切波弹性成像联合MicroPure成像技术对TI-RADS 3、4结节的鉴别诊断价值

张利英 温德惠 李小娟 王月红

四川医学2018,Vol.39Issue(6):701-704,4.
四川医学2018,Vol.39Issue(6):701-704,4.DOI:10.16252/j.cnki.issn1004-0501-2018.06.027

剪切波弹性成像联合MicroPure成像技术对TI-RADS 3、4结节的鉴别诊断价值

The Value of Shear Wave Elastography Combined with MicroPure Imaging in Differential Diagnosis of TI-RADS Category 3 to 4 Nodules

张利英 1温德惠 2李小娟 2王月红3

作者信息

  • 1. 张家口市建国医院功能科,河北 张家口075000
  • 2. 河北北方学院附属第一医院超声医学科,河北 张家口075000
  • 3. 河北北方学院,河北 张家口075000
  • 折叠

摘要

Abstract

Objective To evaluate the value of shear wave elastography(SWE)combined with ultrasonic MicroPure ima-ging in differential diagnosis of category 3 or 4 nodules in thyroid imaging report and data system(TI-RADS). Methods 127 cases of patients with TI-RADS category 3 or 4 thyroid nodules were screened using conventional two-dimensional ultrasonography through assessing the border,aspect ratio and internal echo of the thyroid nodules,156 nodules in total. Every nodule underwent ultrasonic MicroPure imaging and SWE scanning sequentially to acquire Young modulus. The value of MicroPure imaging,SWE or the combi-nation of the two in the diagnosis of TI-RADS category 3 or 4 was compared,with all nodules verified by postoperative pathology or fine needle aspiration(FNA). Results ①The average Young modulus of benign and malignant thyroid nodules was(25. 18 ± 14. 64)kPa and(64. 58 ± 24. 69)kPa,respectively,with statistically significant between-group difference(P<0. 05).②Areas un-der the ROC curve of ultrasonic MicroPure imaging and conventional two-dimensional ultrasonography in the detection of microcal-cification in the nodules were 0. 870 and 0. 577,respectively,the difference being statistically significant(p<0. 05).③The sensi-tivity and accuracy of ultrasonic MicroPure imaging combined with SWE ( 92. 31% and 88. 46%) in differential diagnosis of TI-RADS category 3 or 4 nodules were both higher than those of conventional two-dimensional ultrasonography alone,the difference being statistically significant(P<0 05). Conclusion The combination of SWE and MicroPure imaging on the basis of convention-al two-dimensional ultrasonography can improve the diagnostic accuracy of TI-RADS category 3 or 4 nodules,providing diagnostic basis for clinical treatment.

关键词

剪切波弹性成像技术/超声MicroPure成像技术/甲状腺影像学报告及数据系统/甲状腺结节

Key words

shear wave elastography/ultrasonic micropure imaging/thyroid imaging report and data system/thyroid nodules