| 注册
首页|期刊导航|中国医疗设备|瓦里安Eclipse计划系统中基于云计算的ARC技术的剂量计算时间的探讨

瓦里安Eclipse计划系统中基于云计算的ARC技术的剂量计算时间的探讨

韩阿蒙 张彦秋 李金旺 李秀梅 顾涛 付占昭 毛羽 梁华刚

中国医疗设备2018,Vol.33Issue(7):128-130,134,4.
中国医疗设备2018,Vol.33Issue(7):128-130,134,4.DOI:10.3969/j.issn.1674-1633.2018.07.035

瓦里安Eclipse计划系统中基于云计算的ARC技术的剂量计算时间的探讨

Discussion on the Dose Calculation Time of ARC Technique Based on Cloud Computing in Varian Eclipse Treatment Planning System

韩阿蒙 1张彦秋 2李金旺 2李秀梅 2顾涛 2付占昭 2毛羽 2梁华刚3

作者信息

  • 1. 燕山大学 信息技术中心,河北 秦皇岛 066004
  • 2. 秦皇岛市第一医院肿瘤放疗科,河北 秦皇岛 066000
  • 3. 秦皇岛市第一医院胸外科,河北 秦皇岛 066000
  • 折叠

摘要

Abstract

Objective To explore how to shorten dose calculation time of cloud computing based on ARC technique. Methods Fifteen patients with nasopharyngeal carcinoma were randomly selected. ARC technique was chosen to do the plan and four arc fields were used. Two point five mm was selected as calculation grid size. To do dose calculation for every patient, two workstations with Eclipse was selected firstly and dose calculation time was recorded. Then 4, 5, 6, 7 and 8 workstations were separately selected, and dose calculation time was also recorded. Results The calculation time was the shortest when choosing 6 workstations for dose calculation. The calculation time of 7 workstations and 8 workstations was not shortened, but increased slightly. The average computation time of calling 6 workstations was about 19.1 minutes, which was shorter than that of 2 workstations. At the same time, when Mann-Whitney U test was used to conduct comparing analysis on 6 workstations with 2, 4, 5, 7, 8 workstations, the Z score was separately -4.667,-2.634, -1.348, -0.415 and -1.390, and P value was separately 0.000, 0.008, 0.178, 0.678 and 0.165. Conclusion The computation time of calling 6 workstations was shorter than that of 2 and 4 stations, which had statistical difference. The computation time of calling 6 workstations was shorter than that of 5, 7 and 8 stations, but there was no statistical difference. To increase the number of workstations used to calculation call in a LAN, the dose time can be reduced to a certain extent, and the efficiency of tumor radiotherapy plan designing can be improved.

关键词

放疗计划系统/云计算/ARC技术/计算时间/计划设计

Key words

treatment planning system/cloud computing/ARC technique/calculation time/plan designing

分类

医药卫生

引用本文复制引用

韩阿蒙,张彦秋,李金旺,李秀梅,顾涛,付占昭,毛羽,梁华刚..瓦里安Eclipse计划系统中基于云计算的ARC技术的剂量计算时间的探讨[J].中国医疗设备,2018,33(7):128-130,134,4.

基金项目

2016年河北省科技计划项目(162777171).本论文为教育部科技发展中心互联网应用创新开发平台示范基地(教技发中心函[2012]32号)《互联网应用技术验证试验床》项目研究成果. (162777171)

中国医疗设备

OACSTPCD

1674-1633

访问量7
|
下载量0
段落导航相关论文