| 注册
首页|期刊导航|临床输血与检验|DXH800红细胞新参数在缺铁性贫血中的应用

DXH800红细胞新参数在缺铁性贫血中的应用

田民杰 李艳

临床输血与检验2018,Vol.20Issue(1):76-79,4.
临床输血与检验2018,Vol.20Issue(1):76-79,4.DOI:10.3969/j.issn.1671-2587.2018.01.026

DXH800红细胞新参数在缺铁性贫血中的应用

The New Parameters of Erythrocyte Generated by DXH800 Hematology Analyzer in Clinical Application of Iron Deficiency Anemia

田民杰 1李艳1

作者信息

  • 1. 211100 南京,江苏省南京市江宁医院检验科
  • 折叠

摘要

Abstract

Objective To establish normal reference range of LHD (low hemoglobin density) and MAF(Microcytic Anemia Factor) in the healthy crowds from Jiangning hospital, and to study clinical values in the two parameters' joint detection in the diagnosis of iron deficiency Anemia. Methods To select randomly 180 cases of healthy exam crowds, among which 90 cases were male, and the other 90 cases were female, 54 cases of iron-deficiency anemia IDA and 50 patients with non iron deficiency anemia. Routine blood tests were operated by UniCe?DxH 800, and the hematology analyzer calculates the LHD and MAF, based on the analysis of parameters of MCHC (mean corpuscular hemoglobin concentration), MCV (erythrocyte mean corpuscular volume), and Hb (hemoglobin, Hb).Results the average value of LHD in the healthy control was 2.11%, 95% confidence interval of which was 0.65%~3.79%. The LHD value of males was higher than that of females. The difference was statistically significant (t=4.45, P<0.0l). The average value of MAF was 130, 95% confidence interval of which was 111.35~146.19. The MAF value of males was higher than that of females, the difference was statistically significant (t=9.14, P<0.01). LHD in the IDA group was obviously higher, average of which was 26.19%, compared with the healthy control group, and the difference was statistically significant (t=10.93, P<0.01); There were significant differences in the group of anemia patients with non iron deficiency anemia (t=4.68, P<0.01).There was a significant decline in MAF, the average of which was 78.88, compared with the healthy control group, and the difference was statistically significant (t=26.10, P<0.01).There were significant differences in the group of anemia patients with non iron deficiency anemia (t=7.6, P<0.01). Receiveroperating characteristic (ROC) curve analysis for LHD and MAF in the diagnosis of IDA:cut-off 4.09% and 109.9.The sensitivity and specificity of diagnosis for IDA were higher than MCHC. The sensitivity and specificity of MAF were optimal. Conclusion To establish the reference rang of LHD and MAF in the area of jiangning. LHD and MAF for early diagnosis of IDA has certain clinical significance.

关键词

低血红蛋白密度/小红细胞贫血因子/可信区间/缺铁性贫血

Key words

Low hemoglobin density/Microcytic anemia factor/Confidence interval/Iron deficiency anemia

分类

医药卫生

引用本文复制引用

田民杰,李艳..DXH800红细胞新参数在缺铁性贫血中的应用[J].临床输血与检验,2018,20(1):76-79,4.

临床输血与检验

OACSTPCD

1671-2587

访问量0
|
下载量0
段落导航相关论文