中国实用口腔科杂志2018,Vol.11Issue(5):299-303,5.DOI:10.19538/j.kq.2018.05.009
不同粘接系统及不同类型LED光固化灯对新型氧化锆材料与牙本质粘接强度影响的比较研究
Comparison of the influence of adhesion strength of new zirconia materials and dentin using different adhesive systems and different types of LED curing lights
毕婉婷 1王全禹 2战德松1
作者信息
- 1. 中国医科大学附属口腔医院,辽宁 沈阳 110002
- 2. 中国医科大学附属第一医院鞍山医院,辽宁 鞍山 114011
- 折叠
摘要
Abstract
Objective The new type of zirconia materials and dentin was bondTM d with different adhesive systems, using different types of LED curing lights. By comparing the shear strength, to provide certain theoretical reference for the choice of clinical indications, adhesives systems and curing lights of the new type of restoration. Methods According to the unified standard, maxillary incisors in vitro were selected as experimental samples. Prepared and scanned post space, new type of zirconia post was made by CAD/CAM. Randomly divided into 6 groups, post was respectively bondTM d using 3 kinds of adhesive systems (Panavia F, Multilink N, NX3-Nexus) and 2 kinds of LED lights (ordinary, VALO). Then the samples were horizontally cut into a 1 mm slice. The slices were released in the universal mechanical test machine, the shear strength of each group was analyzed by SPSS 17.0. Results The shear strength of Panavia F was better than that of Multilink N and NX3-Nexus, using the ordinary LED curing light (P < 0.05). Panavia F also had higher shear strength than the other two adhesive systems, using VALO LED curing light (P < 0.05). There was no significant difference in shear strength between the ordinary and VALO light, using the same adhesive systems (P> 0.05). Conclusion The adhesion strength of Panavia F is better than those of Multilink N and NX3-Nexus, using different types of LED curing lights. There is no significant difference in adhesion strength between VALO and ordinary LED curing light, the VALO LED curing light can significantly reduced the operating time by the side of the chair.关键词
氧化锆/粘接系统/光固化灯/剪切强度Key words
zirconia/adhesive system/curing light/shear strength分类
医药卫生引用本文复制引用
毕婉婷,王全禹,战德松..不同粘接系统及不同类型LED光固化灯对新型氧化锆材料与牙本质粘接强度影响的比较研究[J].中国实用口腔科杂志,2018,11(5):299-303,5.