Abstract
Wildfires can cause trips of multiple transmission-lines in a short period and threaten the safe operation of a power grid. The existing key transmission-line evaluation methods are normally based on single factor or subjectively selected factors, thus they are unable to evaluate the key transmission-line under large-scale wildfires comprehensively and reasonably. We put forward a new method for key transmission-line aggregate evaluation based on super efficiency data envelopment analysis. Considering both static operation status and line tripping influence of transmission-lines, we established factors for both two sides, and proposed a new comprehensive key transmission-line evaluation method with multiple factors. We applied the method to a power grid in a wildfire-prone region. The test results show that the method identifies the key transmission-line rapidly and effectively, and thus can provide an auxiliary decision guidance for the safe operation of the power grid.关键词
山火灾害/关键线路辨识/超效率数据包络分析/支路脆弱性评估/安全运行Key words
wildfires disaster/critical lines identification/super-efficiency data envelopment analysis/branch vulnerability assessment/safe operation引用本文复制引用
艾欣,周志宇..山火灾害下电网输电线路关键性评估方法[J].高电压技术,2018,44(8):2433-2441,9.基金项目
国家重点研发计划"智能电网技术与装备"重点专项"支撑低碳冬奥的智能电网综合示范工程"(2016YFB0900500).Project supported by 2016 National Key R & D Program of China to Support Low-carbon Winter Olympics of Integrated Smart Grid Demonstration Project(2016YFB0900500). (2016YFB0900500)