| 注册
首页|期刊导航|高压电器|变压器空载合闸对隔离断路器电子式CT干扰分析及防护

变压器空载合闸对隔离断路器电子式CT干扰分析及防护

白世军 郭乐 曾林翠 刘大亮 张国威 刘浩峰 王小华 荣命哲

高压电器2018,Vol.54Issue(8):81-90,97,11.
高压电器2018,Vol.54Issue(8):81-90,97,11.DOI:10.13296/j.1001-1609.hva.2018.08.013

变压器空载合闸对隔离断路器电子式CT干扰分析及防护

Interference Analysis and Protection of Electronic Current Transformer in DCB During No-load Closing of Transformer

白世军 1郭乐 2曾林翠 3刘大亮 2张国威 3刘浩峰 2王小华 2荣命哲1

作者信息

  • 1. 西安交通大学电气工程学院,西安 710049
  • 2. 西安西电高压开关有限责任公司,西安 710077
  • 3. 江苏西电南自智能电力设备有限公司,南京 210032
  • 折叠

摘要

Abstract

Based on the phenomenon of protection malfunction caused by electronic current transformer abnormal work during the operation no-load closing of transformer in a 220 kV new-generation intelligent substation, depth analysis the cause of electronic current transformer abnormal work, and gives specific measures which by changing the electronic current transformer and collector grounding or by merging unit software filtering to improve the electronic current transformer anti-interference ability in DCB. Through this measures, the problem of disturbance appeared in the project put into operation is successfully solved.

关键词

隔离断路器/电子式CT/感性负载

Key words

disconnecting circuit breaker (DCB)/electronic current transformer (ECT)/inductive load

引用本文复制引用

白世军,郭乐,曾林翠,刘大亮,张国威,刘浩峰,王小华,荣命哲..变压器空载合闸对隔离断路器电子式CT干扰分析及防护[J].高压电器,2018,54(8):81-90,97,11.