| 注册
首页|期刊导航|计算机与数字工程|浪涌抑制器瞬态尖峰电压测试后失效原因分析∗

浪涌抑制器瞬态尖峰电压测试后失效原因分析∗

袁文 张文辉

计算机与数字工程2019,Vol.47Issue(1):52-56,5.
计算机与数字工程2019,Vol.47Issue(1):52-56,5.DOI:10.3969/j.issn.1672-9722.2019.01.014

浪涌抑制器瞬态尖峰电压测试后失效原因分析∗

Failure Analysis of Aurge Auppressor Transient Peak Voltage Test

袁文 1张文辉1

作者信息

  • 1. 贵州航天计量测试技术研究所 贵阳 550009
  • 折叠

摘要

Abstract

In this paper,according to the phenomenon of transient peak voltage test,the failure location of the device failure location and the device internal circuit diagram are analyzed,the circuit principle and related test standards are analyzed,the fault tree is established,the failure reason is analyzed,and the failure of the device is obtained after the transient peak voltage test,and the fault recurrence is proposed,and preventive measures are proposed.

关键词

浪涌抑制器/失效/分析

Key words

Key Words surge arrester/failure/analysis

分类

信息技术与安全科学

引用本文复制引用

袁文,张文辉..浪涌抑制器瞬态尖峰电压测试后失效原因分析∗[J].计算机与数字工程,2019,47(1):52-56,5.