To promote the accuracy and application of arcing time measurement for SF6 circuit breaker in substation,five measurement methods are investigated by two cases experimentally.First,the test results of the five methods for a circuit breaker in different stages of wear and a circuit breaker with a component failure were presented.Then,the time error is analyzed by simulation.Finally,the advantage and disadvantage of these methods are discussed.