高压电器2019,Vol.55Issue(3):1-7,14,8.DOI:10.13296/j.1001-1609.hva.2019.03.001
Research on Online Monitoring Methods on SF6Circuit Breakers
Research on Online Monitoring Methods on SF6 Circuit Breakers
摘要
Abstract
To promote the accuracy and application of arcing time measurement for SF6 circuit breaker in substation,five measurement methods are investigated by two cases experimentally.First,the test results of the five methods for a circuit breaker in different stages of wear and a circuit breaker with a component failure were presented.Then,the time error is analyzed by simulation.Finally,the advantage and disadvantage of these methods are discussed.关键词
circuit breaker/high voltage circuit breaker/arcing time/arc duration/online monitoring/wavelet analysisKey words
circuit breaker/high voltage circuit breaker/arcing time/arc duration/online monitoring/wavelet analysis引用本文复制引用
CHENG Tingting,GAO Wensheng,ZHAO Yuming..Research on Online Monitoring Methods on SF6Circuit Breakers[J].高压电器,2019,55(3):1-7,14,8.基金项目
Project Supported by the Technique Project of China Southern Power Grid Co.,Ltd.(20142001342). (20142001342)