Abstract
Aiming at the safety problems in the information exchange process of the new generation distribution automa?tion master stations,such as external interference,information distortion,and system attack,a safety evaluation meth?od for the information penetration area of the new generation distribution automation master station based on analytic network process(ANP)is proposed in this paper. First,a comprehensive safety evaluation index system is put forward from four aspects,i.e.,operation state,configuration mode,operation condition,and management safety. Then,the typical structure of ANP is described in detail,which is further applied to obtain the weights of the comprehensive eval?uation index system. Finally,through typical practical case studies in Tianjin,the rationality and feasibility of the pro?posed index system and evaluation method are verified.关键词
新一代配电自动化主站/信息穿区/安全性评估/网络层次分析法Key words
new generation distribution automation master station/information penetration area/safety evaluation/ana⁃lytic network process(ANP)分类
信息技术与安全科学引用本文复制引用