节能2019,Vol.38Issue(1):31-33,3.DOI:10.3969/j.issn.1004-7948.2019.01.013
某电厂增设低温省煤器的经济性分析
Effectiveness analysis of installing low pressure economizer in thermal power plant
王操 1彭义林 1田新民1
作者信息
- 1. 湖北省电力勘测设计院有限公司,湖北 武汉 430000
- 折叠
摘要
Abstract
The calculation of low pressure economizer for a 2×150 MW coal-fired thermal power plant in is carried out in this paper. The results show that the installation of a single stage low pressure economizer at the inlet of the dust collector and put recovered heat to condensate water system has the best technology and economy efficiency. Compared with the project without low pressure economizer, heat consumption can be reduced about 71.2 kJ/kWh.关键词
低温省煤器/节能减排/余热利用/热力参数/经济性分析Key words
low temperature economizer/energy-saving and emission reduction/waste heat utilization/thermodynamic parameters/economic analysis分类
能源科技引用本文复制引用
王操,彭义林,田新民..某电厂增设低温省煤器的经济性分析[J].节能,2019,38(1):31-33,3.