节能2019,Vol.38Issue(1):77-81,5.DOI:10.3969/j.issn.1004-7948.2019.01.027
某电厂1000MW火电机组引风机和增压风机优化改造研究与应用
Study and application on optimized transformation of induced draft fan and booster fan in 1000MW thermal power unit
张广才 1陶然 1彭元 1廖朋祥 1钟世鹏1
作者信息
- 1. 广东惠州平海发电厂有限公司,广东 惠州 516363
- 折叠
摘要
Abstract
Since a 1000MW thermal power unit was put into operation, it was found that both the induced draft fan and booster fan were poor in economy and safety, The model selection of induced draft fan was relatively large, and the model selection of booster fan type selection of the booster fan was relatively small, and the risk of induced draft fan stall was high at the low load condition, the risk of booster fan stall was high at the high load condition. This paper analyzes the operation of fan system through the thermal test of fan system, and the optimal transformation scheme is proposed, the influence of the transformation on boiler explosion proof is also evaluated. The booster fans are cancelled through the transformation, the efficient adjustable blade axial fan is adopted to replace the inefficient static blade axial fan, at the same time, the gas flue system is optimized and transformed, which greatly improved the economy and safety of unit operation.关键词
引风机/增压风机/合并改造/风机效率/厂用电/锅炉防爆Key words
induced draft fan/booster fan/merged transformation/fan efficiency/plant electric consumption/boiler explosion proof分类
信息技术与安全科学引用本文复制引用
张广才,陶然,彭元,廖朋祥,钟世鹏..某电厂1000MW火电机组引风机和增压风机优化改造研究与应用[J].节能,2019,38(1):77-81,5.