节能2019,Vol.38Issue(1):98-100,3.DOI:10.3969/j.issn.1004-7948.2019.01.035
安徽省某660MW燃煤机组脱硫超低排放改造方案的研究
Study on the desulfurization ultra-low emission reconstruction plan of a 660MW coal-fired unit in anhui province
李雯1
作者信息
- 1. 大唐环境产业集团股份有限公司大唐电力设计研究院,北京 100097
- 折叠
摘要
Abstract
For a 660 MW coal-fired unit in Anhui province, the original system design desulfurization efficiency is about 95.2%, and the outlet SO2 concentration does not exceed 200 mg/m3. In order to achieve ultra-low emission of desulfurization, the basic situation of the desulfurization system before the desulfurization ultra-low emission engineering transformation of the power plant is mainly described, and the feasibility of implementing three different deep desulfurization transformation technologies on the unit is compared and analyzed, and the 660 MW is obtained. The final desulfurization ultra-low emission transformation plan for coal-fired units.关键词
660 MW燃煤机组/脱硫/超低排放Key words
660 MW coal-fired unit/desulfurization/ultra low emission分类
建筑与水利引用本文复制引用