电气传动2019,Vol.49Issue(1):91-96,6.DOI:10.19457/j.1001-2095.dqcd18350
微电网中改进主动频移式孤岛检测法研究
Research on Improved Active Frequency Drift Islanding Detection in Microgrid
摘要
Abstract
When the microgrid is in the unplanned islanding state,the energy storage inverter successfully detect the islanding is one of its essential functions. For the contradiction between the detection time and the harmonic content of the traditional AFD method ,an improved islanding method ,AFDIQF ,which improved q-axis reactive power perturbation by active frequency drift method was proposed. The method not only made the energy storage inverter with better output power quality when it worked on grid-connected state,but also could detect the islanding state quickly from grid-connected mode to islanded mode and reduce the non-detected zone. Finally,the validity and superiority of the improved islanding detection method proposed were verified by simulation experiments.关键词
孤岛检测/主动频移法/AFDIQF法/检测盲区Key words
islanding detection/active frequency drift method/AFDIQF method/non-detected zone分类
信息技术与安全科学引用本文复制引用
李辉,李肇汉,郭忠涵..微电网中改进主动频移式孤岛检测法研究[J].电气传动,2019,49(1):91-96,6.基金项目
上海市国际科技合作项目(15220710500) (15220710500)
上海市自然科学基金项目(15ZR1417600) (15ZR1417600)