| 注册
首页|期刊导航|国际医药卫生导报|微型外固定架联合克氏针对手指关节内骨折患者关节功能的影响

微型外固定架联合克氏针对手指关节内骨折患者关节功能的影响

陆道军 张彩凤 李方凯 陈夫圆 王鹏飞

国际医药卫生导报2020,Vol.26Issue(1):70-73,4.
国际医药卫生导报2020,Vol.26Issue(1):70-73,4.DOI:10.3760/cma.j.issn.1007-1245.2020.01.021

微型外固定架联合克氏针对手指关节内骨折患者关节功能的影响

Effect of micro external fixator combined with kirschner wire on joint function of patients with intra-articular fractures of the finger

陆道军 1张彩凤 1李方凯 1陈夫圆 1王鹏飞1

作者信息

  • 1. 枣庄矿业集团中心医院手足外科 277000
  • 折叠

摘要

Abstract

Objective To investigate the effect of micro-external fixator combined with kirschner wire internal fixation on the QOL score of patients with intra-articular fractures of the finger.Methods 68 patients with intra-articular fractures of the finger were enrolled in our hospital from February 2018 to January 2019.They were randomly divided into two groups,34 cases in each group.The control group was treated with intraplate surgery,and the study group was treated with micro-external fixator combined with kirschner wire internal fixation.The treatment efficiency,hospitalization time,operation time,fracture healing time,QOL score,and the levels of inflammatory factors were observed and compared.Results The effective rate of treatment in the study group was 94.1%,and that in the control group was 67.6%,the therapeutic effect in the study group was better than that in the control group (P<0.05).The length of stay in the study group [(5.1±0.7) days] was shorter than that in the control group [(7.6±0.9) days],the operation time in the study group [(39.6±5.1) min] was shorter than that in the control group [(80.2±4.8) min],the fracture healing time in the study group [(42.9±8.2) days] was shorter than that in the control group [(58.1±8.1) days],and the clinical indexes in the study group were better than those in the control group (P<0.05).The QOL scores in the study group were (82.5±4.7),(83.3±3.9),(85.7±4.7),and (86.1±4.7),which were significantly higher than those in the control group [(75.2±4.3),(75.2±4.1),(79.6±3.5),and (79.5±3.5)](P<0.05).The levels of inflammatory factors in the study group were lower than those in the control group after treatment (P<0.05).Conclusion The application of micro external fixator combined with kirschner wire internal fixation has a significant effect in the treatment of intra-articular fractures of the finger,which reduces the stiffness of the joints,reduces the operation time required,and makes the finger function recover faster and better,so it can be widely used.

关键词

微型外固定架/克氏针/内固定手术/手指关节内骨折/QOL评分

Key words

Micro external fixator/Kirschner wire/Internal fixation/Intra-articular fracture of the finger/QOL score

引用本文复制引用

陆道军,张彩凤,李方凯,陈夫圆,王鹏飞..微型外固定架联合克氏针对手指关节内骨折患者关节功能的影响[J].国际医药卫生导报,2020,26(1):70-73,4.

国际医药卫生导报

1007-1245

访问量5
|
下载量0
段落导航相关论文