Abstract

The detection range of GB/T 11067.2-2006 method was Extensive research.The experiments were carried out from the aspects of sample weight,sample digestion,matrix removal,detection limit and the influence of interfering impurities.Finally,the detection range of copper measured by gb method is expanded from 0.0005%~0.060%to 0.0002%~0.100%.The expanded detection range is more suitable for practical application and can meet the needs of more silver products.

关键词

原子吸收光谱法//测铜/检测范围/扩展上下限

Key words

aAtomic absorption spectrometry/silver/measuring copper/examination area/extended upper and lower limits