| 注册
首页|期刊导航|电瓷避雷器|基于ZNy11-Dyn7型无源降压消弧器件的高阻接地故障选线新方法

基于ZNy11-Dyn7型无源降压消弧器件的高阻接地故障选线新方法

陈虓 刘红文 黄继盛 喻锟 曾祥君 曾超

电瓷避雷器Issue(6):45-54,10.
电瓷避雷器Issue(6):45-54,10.DOI:10.16188/j.isa.1003-8337.2023.06.006

基于ZNy11-Dyn7型无源降压消弧器件的高阻接地故障选线新方法

New Method for High-Resistance-Grounding-Fault Line Selection Based on ZNy11-Dyn7 Passive Step-Down Arc Suppression Device

陈虓 1刘红文 2黄继盛 1喻锟 3曾祥君 3曾超3

作者信息

  • 1. 云南电网有限责任公司临沧供电局,云南 临沧 677000
  • 2. 云南电网有限责任公司电力科学研究院,昆明 650217
  • 3. 智能电网运行与控制湖南省重点实验室(长沙理工大学电气与信息工程学院),长沙 410114
  • 折叠

摘要

Abstract

The existing grounding fault line selection methods are affected by system parameter asymmetry and asynchronous transformer sampling,which makes it difficult to accurately distinguish high resistance grounding fault feeder lines,the author proposes a new method for high resistance grounding fault line se-lection based on ZNy11-Dyn7 passive step-down arc suppression device.Firstly,a passive voltage regulation structure based on ZNy11-Dyn7 transformer was proposed,and the operational characteristics of ZNy11-Dyn7 passive step-down and arc suppression devices after being connected to the system were analyzed.Based on the voltage regulation principle of ZNy11-Dyn7 passive components,before and after a ground fault occurs in the system,the voltage of the system is regulated through the input of passive components.The zero sequence admittance values of each feeder before and after the fault are calculated to eliminate the influence of system parameter asymmetry and asynchronous transformer sam-pling.The zero sequence admittance phase difference of each feeder before and after the fault is actively constructed,achieving accurate identification of the faulty line.Under PSCAD/EMTDC environment,a 10 kV distribution network ground fault model is built to verify the effectiveness of the proposed line selec-tion method.The results show that the proposed method can accurately identify fault lines when different transition resistance grounding faults occur in ungrounded system and resonant grounding system,and the resistance to transition resistance can reach 24 kΩ.

关键词

高阻故障/无源降压消弧器件/ZNy11-Dyn7型变压器/电压调控/故障选线

Key words

high resistance fault/passive arc suppression device/ZNy11-Dyn7 transformer/voltage re-gulation/fault line selection

引用本文复制引用

陈虓,刘红文,黄继盛,喻锟,曾祥君,曾超..基于ZNy11-Dyn7型无源降压消弧器件的高阻接地故障选线新方法[J].电瓷避雷器,2023,(6):45-54,10.

基金项目

云南电网有限责任公司科技项目(编号:YNKJXM20210175).Project supported by Science and Technology Program of Yunnan Power Grid Co.,Ltd.(No.YNKJXM20210175). (编号:YNKJXM20210175)

电瓷避雷器

1003-8337

访问量0
|
下载量0
段落导航相关论文