| 注册
首页|期刊导航|林产化学与工业|活性炭电极数量对电容去离子系统脱盐性能的影响

活性炭电极数量对电容去离子系统脱盐性能的影响

檀畅 李蓓 呼生春 王傲 张燕萍 孙康

林产化学与工业2023,Vol.43Issue(6):17-24,8.
林产化学与工业2023,Vol.43Issue(6):17-24,8.DOI:10.3969/j.issn.0253-2417.2023.06.003

活性炭电极数量对电容去离子系统脱盐性能的影响

Effect of the Number of Activated Carbon Electrodes on the Desalination Performance of Capacitive Deionization

檀畅 1李蓓 2呼生春 1王傲 1张燕萍 1孙康1

作者信息

  • 1. 中国林业科学研究院 林产化学工业研究所,江苏省生物质能源与材料重点实验室,国家林业和草原局林产化学工程重点实验室,林木生物质低碳高效利用国家工程研究中心,江苏省林业资源高效加工利用协同创新中心,江苏 南京 210042
  • 2. 江苏省中国科学院植物研究所,江苏 南京 210014
  • 折叠

摘要

Abstract

This study constructed capacitive deionization(CDI)systems with different numbers of stacked units,using activated carbon as electrode material without ion exchange membranes.The effects of the number of stacked units on freshwater productivity,salt adsorption capacity and energy efficiency of the CDI system were explored.The results show that CDI systems with 1,2,and 4 pairs of electrodes achieve the total salt removal quantity of 10.11,23.41,and 34.22 mg at the same flow rate,respectively.Furthermore,the average concentration reduction(ΔC)and the thermodynamic energy efficiency(ηTEE)of the CDI systems increase dramatically with the increase of the electrode units:ΔC increased from 2.16 mmol/L to 7.31 mmol/L,and ηTEE increased from 0.66%to 2.17%.In the CDI system with two pairs of electrodes,the charge efficiency and the salt adsorption capacity(QSAC)do not be affected by the flow rate,while the ΔC,energy consumption,and ηTEE of the system all significantly decrease with the increase of the flow rate.In addition,when simultaneously increasing the stacked units and flow rate with the same factor,the total salt removal quantity of the CDI system was 10.11,22.25 and 32.89 mg at the stacked units of 1,2,4,respectively.All of these three systems achieve the average desalination concentration of about 2 mmol/L.Therefore,increasing the number of stacked units can effectively expand the scale of CDI system.

关键词

电容去离子/活性炭/苦咸水淡化/工业化放大

Key words

capacitive deionization/activated carbon/brackish water desalination/scale up

分类

化学化工

引用本文复制引用

檀畅,李蓓,呼生春,王傲,张燕萍,孙康..活性炭电极数量对电容去离子系统脱盐性能的影响[J].林产化学与工业,2023,43(6):17-24,8.

基金项目

江苏省生物质能源与材料重点实验室重大项目(JSBEM-S-202101) (JSBEM-S-202101)

中国博士后科学基金资助项目(2021M691337) (2021M691337)