摘要

Abstract

The static lobe-regulated steam induced draft fan was retrofitted into a two-stage dynamic lobe-regulated steam induced draft fan in a 660MW supercritical power plant,which solved the problems of resonance of the static lobe-regulated steam induced draft fan,easy to stall at low loads,and difficult to merge into the induced draft fan,and at the same time,it improved the performance of the fan,and lowered the steam consumption of the steam induced draft fan for the small steam turbine.

关键词

汽动引风机/静叶调节/双级动叶调节/节能/风机失速/共振

Key words

steam driven/induced draft fan/stationary blade adjustment/two-stage moving blade adjustment/energy saving/fan stall/resonance