| 注册
首页|期刊导航|品牌与标准化|紫外可见分光光度计检定中的误差分析与控制

紫外可见分光光度计检定中的误差分析与控制

严子翔

品牌与标准化Issue(1):213-215,3.
品牌与标准化Issue(1):213-215,3.DOI:10.3969/j.issn.1674-4977.2024.01.066

紫外可见分光光度计检定中的误差分析与控制

Error Analysis and Control in Calibration of UV-Visible Spectrophotometers

严子翔1

作者信息

  • 1. 桂林市计量测试研究所,广西 桂林 541004
  • 折叠

摘要

Abstract

This article combines the verification procedures of JJG 178-2007 Ultraviolet,Visible,Near-Infrared Spectrophotometers to analyze the calibration items of ultraviolet-visible spectrophotometers.It elucidates the main sources of errors in the calibration of ultraviolet-visible spectrophotometers and further analyzes the causes of these errors.Corresponding control methods are proposed for various error sources to ensure the accuracy of the calibration of ultraviolet-visible spectrophotometers.

关键词

紫外可见分光光度计/检定/误差分析

Key words

UV-visible spectrophotometers/verification/error analysis

引用本文复制引用

严子翔..紫外可见分光光度计检定中的误差分析与控制[J].品牌与标准化,2024,(1):213-215,3.