品牌与标准化Issue(1):213-215,3.DOI:10.3969/j.issn.1674-4977.2024.01.066
紫外可见分光光度计检定中的误差分析与控制
Error Analysis and Control in Calibration of UV-Visible Spectrophotometers
严子翔1
作者信息
- 1. 桂林市计量测试研究所,广西 桂林 541004
- 折叠
摘要
Abstract
This article combines the verification procedures of JJG 178-2007 Ultraviolet,Visible,Near-Infrared Spectrophotometers to analyze the calibration items of ultraviolet-visible spectrophotometers.It elucidates the main sources of errors in the calibration of ultraviolet-visible spectrophotometers and further analyzes the causes of these errors.Corresponding control methods are proposed for various error sources to ensure the accuracy of the calibration of ultraviolet-visible spectrophotometers.关键词
紫外可见分光光度计/检定/误差分析Key words
UV-visible spectrophotometers/verification/error analysis引用本文复制引用
严子翔..紫外可见分光光度计检定中的误差分析与控制[J].品牌与标准化,2024,(1):213-215,3.