冷自身抗体伴IgG抗-S致配血不合1例
Blood matching incompatibility caused by cold autoantibodies and IgG anti S antibody:a case report
马晨1
作者信息
- 1. 淄博市中心血站,山东 淄博 255000
- 折叠
摘要
Abstract
Objective To analyze the serological characteristics of an anemia patient with cold autoantibodies and IgG anti S antibody.Methods Unexpected antibody screening was performed on screening cells,autologous cells and panel cells with patient serum in saline and anti human globulin card media at room temperature and 37℃,respectively.At the same time,the serum that destroying IgM antibodies and acid elution solution were respectively screened for unexpected antibodies in anti human globulin card media.The absorption-elution test was used to treat patients′red blood cells and serum,and the unexpected antibody identification and cross matching were performed after excluding the interference of cold autoantibodies.Results Cold autoantibodies and IgG anti S antibody were found in the serum of this patient.Conclusion When a patient is found to have cold autoantibodies,it is necessary to screen the alloantibody,in order to avoid post transfusion immune re-actions due to missed detection of alloantibody.关键词
冷自身抗体/抗-S抗体/交叉配血/输血安全Key words
cold autoantibodies/anti S antibody/cross matching/transfusion safety分类
医药卫生引用本文复制引用
马晨..冷自身抗体伴IgG抗-S致配血不合1例[J].中国输血杂志,2023,36(12):1165-1167,3.