首页|期刊导航|临床误诊误治|多层螺旋CT及MRI检查对听神经瘤的诊断效能比较

多层螺旋CT及MRI检查对听神经瘤的诊断效能比较OACSTPCD

Comparison of Diagnostic Efficacy of Multi-slice Spiral CT and MRI in Acoustic Neuroma

中文摘要英文摘要

目的 对比多层螺旋CT(MSCT)及MRI检查对听神经瘤诊断效能.方法 回顾分析 2019 年 4 月—2021 年7 月收治的86 例听神经瘤临床资料.比较MSCT、MRI及二者联合对听神经瘤诊断效能,并分析听神经瘤MSCT、MRI特征.结果 MRI联合MSCT诊断听神经瘤准确率95.35%(82/86),明显高于单一MRI诊断的 84.88%(73/86)、MSCT诊断的72.09%(62/86)(P<0.05).MSCT平扫可见类圆形肿块,…查看全部>>

Objective To compare the diagnostic efficacy of multi-slice spiral CT(MSCT)and MRI in acoustic neuro-ma.Methods The clinical data of 86 patients with acoustic neuroma treated from April 2019 to July 2021 were retrospectively analyzed.The diagnostic efficacy of MSCT,MRI and their combined examination in acoustic neuroma was compared,and the MSCT and MRI characteristics of acoustic neuroma were analyzed.Results The accuracy of MRI combined with MSCT in the dia…查看全部>>

陈荣;蒋永明;唐聪;殷成坤;沈小程

629000 四川 遂宁,遂宁市中心医院放射科629000 四川 遂宁,遂宁市中心医院放射科629000 四川 遂宁,遂宁市中心医院放射科629000 四川 遂宁,遂宁市中心医院放射影像科629000 四川 遂宁,遂宁市中心医院放射影像科

临床医学

神经瘤,听多层螺旋CT磁共振成像平扫增强扫描影像学特征诊断效能

Neuroma,acousticMulti-slice spiral CTMagnetic resonance imagingPlain scanEnhanced scan-ningImaging featureDiagnostic efficacy

《临床误诊误治》 2023 (7)

68-71,4

遂宁市中心医院2022年院级科研课题(2022ypj05)