| 注册
首页|期刊导航|内蒙古电力技术|燃煤锅炉SCR脱硝系统及其流场优化研究

燃煤锅炉SCR脱硝系统及其流场优化研究

王轶 张健 樊雄飞 顾超 何宝晶 李伟 李兵 伍力拓 杨浩 杨祖旺

内蒙古电力技术2023,Vol.41Issue(6):26-34,9.
内蒙古电力技术2023,Vol.41Issue(6):26-34,9.DOI:10.19929/j.cnki.nmgdljs.2023.0081

燃煤锅炉SCR脱硝系统及其流场优化研究

Research on SCR Denitrification System and Its Flow Field Optimization for Coal-Fired Boilers

王轶 1张健 2樊雄飞 1顾超 1何宝晶 1李伟 1李兵 1伍力拓 2杨浩 2杨祖旺2

作者信息

  • 1. 青铜峡铝业发电有限责任公司,陕西 青铜峡 751600
  • 2. 西安格瑞电力科技有限公司,西安 710000
  • 折叠

摘要

Abstract

In order to address the difficulty of precise ammonia injection in the Selective Catalytic Reduction(SCR)system during the transient process of coal-fired power units,the author optimizes the outlet flue guide plate and SCR top guide plate of the economizer of a coal-fired boiler based on numerical calculation results,establishes a controlled system and dynamic response model,and improves the model online using artificial intelligence algorithms to achieve precise ammonia injection.After the renovation,the flue gas flow rates on the A and B sides of the SCR inlet flue are 9.0 m/s and 9.2 m/s respectively,with relative standard deviation(CV)values of 11.4%and 10.7%.The average concentrations of NOx on the A and B sides of the SCR inlet flue are 250.7 mg/m3 and 260.5 mg/m3 respectively,with CV values of 4.8%and 5.0%.The average NOx on the A and B sides of the SCR outlet flue are 47.1 mg/m3 and 51.6 mg/m3 respectively,with CV values of 12.3%and 12.5%.These values meet the requirements of ultra-low emissions.The unit consumption of liquid ammonia decreases from 0.2783 kg per MWh before the renovation to 0.2152 kg per MWh,with a decrease of 27.8%.

关键词

燃煤锅炉/SCR优化/精准喷氨/流场优化/脱硝系统

Key words

coal-fired boiler/SCR optimization/precise ammonia injection/flow field optimization/denitrification system

分类

信息技术与安全科学

引用本文复制引用

王轶,张健,樊雄飞,顾超,何宝晶,李伟,李兵,伍力拓,杨浩,杨祖旺..燃煤锅炉SCR脱硝系统及其流场优化研究[J].内蒙古电力技术,2023,41(6):26-34,9.

基金项目

青铜峡铝业发电有限责任公司科技项目"2号机组SCR脱硝系统智能测控及调平系统技术研究及应用"(QIOLED-JG-2022-08-29) (QIOLED-JG-2022-08-29)