Based on the analyses of the main technical parameters of the pump-turbines of pumped-storage power stations built at home and abroad the relationship between the head and the unit capacity and other parameters of the fixed-speed mixed-flow pump-turbine is studied the selection principles of unit capacity and coefficient of specific speed for these pump-turbines with different operation head range are put forward and the suitable rated speed ranges for these pump-turbines are also recommended.The research can improve the work efficiency and quality of pump-turbine selection design for pumped-storage power stations.关键词
抽水蓄能/混流式水泵水轮机/水头/单机容量/比速系数/额定转速Key words
pumped storage/mixed-flow pump-turbine/head/unit capacity/coefficient of specific speed/rated speed分类