| 注册
首页|期刊导航|口腔疾病防治|种植钉植入高度对隐形矫治远移下磨牙时应力分布的影响

种植钉植入高度对隐形矫治远移下磨牙时应力分布的影响

王宋庆 康芙嘉 袁佳敏 朱宪春

口腔疾病防治Issue(3):188-195,8.
口腔疾病防治Issue(3):188-195,8.DOI:10.12016/j.issn.2096-1456.2024.03.004

种植钉植入高度对隐形矫治远移下磨牙时应力分布的影响

Effect of miniscrew placement height on the distribution of biological forces produced by clear aligner for man-dibular molar distalization

王宋庆 1康芙嘉 1袁佳敏 1朱宪春1

作者信息

  • 1. 吉林大学口腔医院正畸科,吉林长春(130000)
  • 折叠

摘要

Abstract

Objective To explore the effect of different miniscrew placement heights on the distribution of biologi-cal forces produced by clear aligner combined with intramaxillary traction for mandibular molar distalization,to identify the miniscrew location that is conducive to the protection of lower anterior tooth anchorage and to provide a reference that can be used when designing clinical treatments.Methods Mimics,GeomagicStudio 2017,SolidWorks 2016,and Ansys workbench were used to establish finite element analysis models and perform mechanical analysis under the fol-lowing six working conditions:working condition 1 was the control group without miniscrews;working conditions 2 to 5 had miniscrew in the buccal bone cortex between the first and second molars of the lower jaw 10 mm,7 mm,4 mm,and 1 mm from the top of the alveolar crest,respectively;working condition 6 had the miniscrew in the center of the buccal tongue at the anterior edge of the ascending branch of the lower jaw 5 mm above the occlusal plane.Results On the sagittal axis,miniscrew anchorage caused distal displacement of all teeth.Compared to the control group,in the miniscrew group,the displacement of the anterior molars exceeded that of the second molars.On the vertical axis,the result in the control group was similar to backward bending;the results in the miniscrew groups resembled the effect of a lever,lowering the lateral incisors and canines and raising the central incisors and first premolars.On the coronal ax-is,the second premolars and the first molars showed lingual displacement in the control group,and only the premolars and first molars showed lingual displacementin the miniscrew groups.The canines were the teeth that were most strong-ly affected by the change in miniscrew placement height.Conclusion The higher the miniscrew position is,the stron-ger the protective effect on the anterior anchorage.According to the miniscrew placement height,the mandibular arch should be properly narrowed,the central incisors and first premolars should be lowered,and the lateral incisors and ca-nines should be raised when designing clinical treatments.

关键词

下颌骨/错畸形/正畸/无托槽隐形矫治器/支抗/微螺钉种植体/牙齿应力分析/有限元分析

Key words

mandible/malocclusion/orthodontics/clear aligner/anchorage/miniscrew implant/dental stress analysis/finite element analysis

分类

医药卫生

引用本文复制引用

王宋庆,康芙嘉,袁佳敏,朱宪春..种植钉植入高度对隐形矫治远移下磨牙时应力分布的影响[J].口腔疾病防治,2024,(3):188-195,8.

基金项目

This study was supported by the grants from National Natural Science Foundation of Jilin Province(No.YDZJ202201ZYTS057).吉林省自然科学基金(YDZJ202201ZYTS057) (No.YDZJ202201ZYTS057)

口腔疾病防治

OACSTPCD

1006-5245

访问量0
|
下载量0
段落导航相关论文