The first order inertial control deviation item of the cold water valve causes the poor control effect of headroom temperature regulation and humidity.Therefore,a first-order inertia lag PID independ-ent control method for chilled water valve of clean air conditioner is proposed.In this method,the first or-der inertia lag model of the environment and the cold water valve is established considering the basic infor-mation of the indoor environment;the fresh air volume of indoor clean air conditioning temperature and hu-midity is calculated as the constraint of independent control of temperature and humidity of the cooling wa-ter valve of clean air conditioning;the adaptive immune genetic algorithm is used to optimize the parame-ters of PID controller,based on which the independent control of the temperature and humidity of the cool-ing water valve of the clean air-conditioning is realized.The experimental results show that the method is effective and energy-saving.

关键词

冷水阀门/变参数PID/空调温湿度/独立控制/自适应免疫遗传算法/一阶惯性滞后

Key words

cold water valve/variable parameter PID/air conditioning temperature and humidity/inde-pendent control/adaptive immune genetic algorithm/first order inertia lag