摘要
Abstract
The content of active components Sb,Bi,B,Mg,Al,La,Ce and Sn in catalytic cracking metal deactivator samples was determined by inductively coupled plasma emission spectrometry with inorganic and organic injection methods.The analysis conditions of spectral lines,radio frequency power and atomizer flow of each element were optimized on the two sampling methods.The type and amount of digestive acid and the type of diluent for organic dilution were determined,and the accuracy of the method was investigated.The experimental results show that the content of active components Sb,Bi,B,Mg,Al,La,Ce and Sn in catalytic cracking metal deactivator samples can be determined by inductively coupled plasma emission spectrometry.The correlation coefficient of the correction curve for each element is greater than 0.999,the relative standard deviation is less than 5%,and the recovery rate is between 92%and 107%,which can meet the requirements of analysis.关键词
催化裂化金属钝化剂/电感耦合等离子体发射光谱/消解酸/稀释剂Key words
catalytic cracking metal deactivator/inductively coupled plasma emission spectrum/digestive acid/diluent分类
化学化工