| 注册
首页|期刊导航|中国医疗设备|Catalyst光学体表监测在左侧乳腺癌ABC-DIBH放射治疗中的应用

Catalyst光学体表监测在左侧乳腺癌ABC-DIBH放射治疗中的应用

刘剑锋 钟鹤立 张光伟 吴何苟 刘婷婷 高勇 李彬

中国医疗设备2024,Vol.39Issue(1):61-66,6.
中国医疗设备2024,Vol.39Issue(1):61-66,6.DOI:10.3969/j.issn.1674-1633.2024.01.011

Catalyst光学体表监测在左侧乳腺癌ABC-DIBH放射治疗中的应用

Application of Catalyst Optical Body Surface Monitoring in ABC-DIBH Radiotherapy for Left Side Breast Cancer

刘剑锋 1钟鹤立 1张光伟 1吴何苟 1刘婷婷 1高勇 1李彬1

作者信息

  • 1. 深圳市人民医院 肿瘤放疗科,广东 深圳 518020
  • 折叠

摘要

Abstract

Objective To investigate the use of optical body surface tracking technology to monitor the effectiveness of breath holding and the repeatability of body position in deep inspiration breath hold radiotherapy for left breast cancer using active breathing control(ABC)technology,so as to ensure the consistency of inspiratory mode of patients in radiotherapy,reduce body position changes,and improve the accuracy of radiotherapy.Methods A total of 23 patients with left side breast cancer who were treated with ABC technology were monitored with Catalyst during the treatment of DIBH position,and the error data of both were recorded respectively with intra-session cone beam computed tomography(CBCT)as the reference standard.The correlation between the two groups of errors and the consistency of the two systems was evaluated by the Pearson method and the Bland-Altman method.The deduction of CBCT registration error value from the monitoring value of optical body surface was defined as the accuracy of Catalyst body surface monitoring.Results The deviation of the errors in the x,y and z translation directions monitored by Catalyst were(0.08±1.04),(1.44±2.15),and(0.45±1.69)mm,respectively.The CBCT registration values were(0.15±1.15),(1.51±2.28),and(0.44±1.81)mm,respectively.The r values of x direction and z direction were 0.60 and 0.77 respectively,showing a strong correlation,while the r-values of y direction were 0.82,showing a very strong correlation.95%CI values in the translation direction of x,y and z axis were[-2.01,1.86]、[-2.69,2.57]、[-2.32,2.34]mm respectively.The monitoring precision of x,y and z directions were(-0.08±0.99),(-0.06±1.34),(0.01±1.19)mm respectively.Conclusion Catalyst can effectively monitor the breath holding status of left breast cancer patients treated with ABC,accurately and real-time monitor the patient's position,improve the treatment accuracy,and have clinical application value.

关键词

Catalyst/光学体表追踪/主动呼吸控制/左侧乳腺癌/放射治疗

Key words

Catalyst/optical body surface tracking/active breathing control/left side breast cancer/radiotherapy

分类

医药卫生

引用本文复制引用

刘剑锋,钟鹤立,张光伟,吴何苟,刘婷婷,高勇,李彬..Catalyst光学体表监测在左侧乳腺癌ABC-DIBH放射治疗中的应用[J].中国医疗设备,2024,39(1):61-66,6.

基金项目

国家自然科学基金面上项目(61871374). (61871374)

中国医疗设备

OACSTPCD

1674-1633

访问量0
|
下载量0
段落导航相关论文