| 注册
首页|期刊导航|中国斜视与小儿眼科杂志|OCT与眼底照相法测量客观眼球旋转角度的一致性分析研究

OCT与眼底照相法测量客观眼球旋转角度的一致性分析研究

王欣悦 封利霞 汪枫

中国斜视与小儿眼科杂志2023,Vol.31Issue(4):23-24,后插1-后插4,6.
中国斜视与小儿眼科杂志2023,Vol.31Issue(4):23-24,后插1-后插4,6.DOI:10.3969/J.ISSN.1005-328X.2023.04.006

OCT与眼底照相法测量客观眼球旋转角度的一致性分析研究

Consistency analysis of objective ocular torsion measured with OCT and fundus photography

王欣悦 1封利霞 1汪枫1

作者信息

  • 1. 230022 安徽医科大学第一附属医院眼科
  • 折叠

摘要

Abstract

Objective To evaluate the consistency of optical coherence tomography(OCT)and fundus photography in measuring the objective ocular torsion of strabismus patients,and the effectiveness of its application in young chil-dren.Methods One hundred and fifty patients(113 patients over 7 years old and 37 patients under 7 years old)who were to undergo strabismus surgery in the First Affiliated Hospital of Anhui Medical University were selected.On the same day before operation,the fovea-disc angle(FDA)was measured by OCT and fundus photography.OCT software positioned automatically the macula and the center of the optic disc to measure the FDA during scanning.The fundus photographs were imported into Adobe Photoshop software,and the FDA was measured manually.The measurement results of the two methods are compared.Results Among 113 patients over 7 years old and 37 patients under 7 years old,there were no sta-tistical differences between the measurement results of OCT and fundus photography(P<0.05),but there were statistical differences between the results of the right eye and the left eye by the same method(P<0 05).Person correlation analysis showed that there were strong positive correlation between the measurement results of the two methods both the right eye and the left eye of patients over 7 years old and those under 7 years old(P<O.01).Bland-Altman analysis showed that the measurement results of the right eye and the left eye of the two methods were in good agreement both patients over 7 years old and under 7 years old.The analysis of intra-group correlation coefficient(ICC)showed that the measurement results of OCT and fundus photography had good repeat-ability(ICC>0.9),and the repeatability of OCT was better than that of fundus photography.Conclusions OCT can measure the objective ocular torsion more conveniently and quickly,and with good repeatability,it is feasible to be applied to young children,which is replaceable compared with the traditional fundus photography.

关键词

客观眼球旋转角度/光学相干断层扫描/黄斑中心凹-视盘中心夹角/眼底照相

Key words

Objective ocular torsion/Optical coherence tomography(OCT)/Fovea-disc angle(FDA)/Fundus photography

引用本文复制引用

王欣悦,封利霞,汪枫..OCT与眼底照相法测量客观眼球旋转角度的一致性分析研究[J].中国斜视与小儿眼科杂志,2023,31(4):23-24,后插1-后插4,6.

基金项目

安徽医科大学校青年科学基金项目(2022xkj153) (2022xkj153)

中国斜视与小儿眼科杂志

OACSTPCD

1005-328X

访问量0
|
下载量0
段落导航相关论文