Abstract

In order to explore the factors affecting the process start-up of anaerobic moving bed biofilm reactor at low temperature and obtain the optimal start-up process parameters,an experimental platform was established on the basis of selecting K3 filler packing as the reactor filler with natural inoculation process.Under different levels of filling rate,reflux ratio and hydraulic retention time at the water tem-perature of 8-12℃,and different operating conditions the operating effects of the reactor were ob-tained by studying on the treatment effect of the reactor during film hanging start-up on chemical oxygen demand,NH3-H and total phosphorus in sewage.The growth rate of biofilm under different op-erating conditions was obtained by studying on the mass changes of biofilm on the filler in the reactor.By studying the gas production rates of the biofilm,the total specific respiratory rates and endogenous sources specific respiratory rates of the biofilm in the reactor under different operating conditions were obtained.By comparing the operating efficiency,the activity and respiratory rates of the biofilm,the optimal process parameters for the start-up of the A/MBBR with natural inoculation process at 8-12℃ were obtained:the filling rate was 40%,the reflux ratio was 20%,and the hydraulic retention time was 8 h.Under this operating condition,it can take into account the removal rate of pollutants,biofilm growth rate,and biofilm activity.It is the best starting condition and is expected to shorten the starting time by 23%.

关键词

高寒缺氧地区/农村生活污水/A/MBBR反应器/快速启动/工艺参数

Key words

frigid and anoxic areas/rural domestic sewage/A/MBBR/rapid start-up/process parameters

分类

资源环境

引用本文复制引用

董进波,王帆,阿琼,解清杰,韩松..低温下A/MBBR反应器快速启动的工艺参数[J].排灌机械工程学报,2024,42(1):95-101,7.

基金项目

西藏自治区科技厅重点研发计划项目(XZ202201ZY0018N,XZ202301ZY0002N) (XZ202201ZY0018N,XZ202301ZY0002N)

镇江市科技计划项目(社会发展)(SH2021012) (社会发展)

排灌机械工程学报

OA北大核心CSCDCSTPCD

1674-8530

访问量0
|
下载量0
段落导航相关论文