天然气与石油2023,Vol.41Issue(6):117-121,154,6.DOI:10.3969/j.issn.1006-5539.2023.06.016
一种混合型杂散电流排除方法
A hybrid method for eliminating stray current interference
摘要
Abstract
In the operation and management of long-distance transmission pipelines,two independent stray current draining facilities are usually required to eliminate the impact of DC interference and AC interference on the pipeline respectively,as the two types of interference on the pipeline cannot be eliminated by one set of current draining facilities simultaneously.In order to solve this problem,a comprehensive analysis of the interference impact of a gas transmission pipeline was carried out,and a hybrid stray current elimination method was proposed,which used AC and DC dual-purpose stray current drain unit + special discharge bed to form a set of hybrid discharge facilities,so as to eliminate the AC interference and DC interference on the pipeline at the same time,and ensure the safe operation of the pipeline.The system has passed field trials and tests and achieved remarkable results.The hybrid stray current elimination method can eliminate two different stray currents at the same time,thereby reduces the land acquisition area and minimizes environmental impact of the project.关键词
交流杂散电流干扰/直流杂散电流干扰/混合型排流设施Key words
AC stray current interference/DC stray current interference/Hybrid stray current-draining facility引用本文复制引用
高崇林,杨春生,陈虹锦,熊娟,汤雨霖,熬波,蔡强,陈彬源..一种混合型杂散电流排除方法[J].天然气与石油,2023,41(6):117-121,154,6.基金项目
中国石油工程建设有限公司科研项目"集输工程绝缘接头工艺安装及非保护侧腐蚀防护技术"(KY-2020-205) (KY-2020-205)