| 注册
首页|期刊导航|新发传染病电子杂志|γ干扰素释放试验在基层门诊肺结核筛查中的应用及评价

γ干扰素释放试验在基层门诊肺结核筛查中的应用及评价

刘昌伟 马玲娣 魏振华 蒋淑萍 李斌 王艳 黄敏聪

新发传染病电子杂志2023,Vol.8Issue(6):63-68,6.
新发传染病电子杂志2023,Vol.8Issue(6):63-68,6.DOI:10.19871/j.cnki.xfcrbzz.2023.06.012

γ干扰素释放试验在基层门诊肺结核筛查中的应用及评价

Application and evaluation of γ-interferon releasing test in tuberculosis screening in general practice outpatients

刘昌伟 1马玲娣 2魏振华 1蒋淑萍 2李斌 2王艳 1黄敏聪2

作者信息

  • 1. 深圳市龙华区慢性病防治中心结核病防治科,广东 深圳 518000
  • 2. 深圳市龙华区慢性病防治中心检验科,广东 深圳 518000
  • 折叠

摘要

Abstract

Objective Through the clinical application of γ interferon release Assay(IGRA)in primary outpatient tuberculosis screening,the application effect and influencing factors can be evaluated to provide reference opinions for correct and reasonable clinical use.Method 3073 suspected newly diagnosed pulmonary tuberculosis patients who were treated at the Longhua District Chronic Disease Prevention and Control Center in Shenzhen from January 2021 to December 2022 were selected,and sputum samples were collected using acid-fast stain(AFS),BACTEC-MGIT 960 liquid culture method,and other methods crossing-primer amplification(CPA)technology was used to detect Mycobacterium tuberculosis(MTB)in sputum samples before treatment.Peripheral blood samples were collected for IGRA,and positive MGIT 960 liquid culture was used as the reference standard for tuberculosis infection.Clinical diagnosis was used as the diagnostic criterion to evaluate the detection efficiency of IGRA and other methods for tuberculosis infection.Result There is a significant statistical difference in the positive detection rate of IGRA among patients of different ages,with the highest positive detection rate in the 30-40 year old group and the lowest in the 0-10 year old group,with males being higher than females(P<0.01).Among several methods,the overall diagnostic accuracy of culture and CPA were 77.62%and 66.88%,respectively,which were significantly better than IGRA.The sensitivity and specificity of IGRA were 72.89%and 40.96%,respectively,with an overall diagnostic accuracy of only 59.04%.IGRA combined with culture or CPA can significantly improve detection sensitivity(86.89%and 84.22%),but there is no significant improvement in overall diagnostic efficiency(67.39%vs 77.62%,65.86%vs 66.88%).The clinical diagnostic accuracy of IGRA for confirmed tuberculosis patients was 72.89%,with a false negative rate of 27.11%.The clinical diagnostic accuracy with non tuberculosis patients was 40.96%(136/332),with a false positive rate of 59.34%.The positive and negative predictive values for tuberculosis diagnosis were significantly lower than those of culture.There was no significant difference in the detection rate of IGRA for bacterial negative tuberculosis and bacterial positive tuberculosis(χ2=0.147,P=0.7014).Conclusion Although IGRA has good sensitivity,there are certain false positive and false negative rates in practical applications.Compared to pathogen detection,it has advantages in early screening of target disease or close contacts.However,its effectiveness in eliminating tuberculosis is insufficient,and it can be combined with other methods to improve its detection efficiency.

关键词

结核分枝杆菌/痰培养/交叉引物恒温扩增技术/γ干扰素释放试验/对比分析

Key words

Mycobacterium tuberculosis/Phlegm culture/Crossing-primer amplification/Interferon gamma release assay/Comparative analysis

分类

医药卫生

引用本文复制引用

刘昌伟,马玲娣,魏振华,蒋淑萍,李斌,王艳,黄敏聪..γ干扰素释放试验在基层门诊肺结核筛查中的应用及评价[J].新发传染病电子杂志,2023,8(6):63-68,6.

基金项目

深圳市龙华区科技创新局人才专项资助资金科技项目(2020051) (2020051)

新发传染病电子杂志

OACSTPCD

2096-2738

访问量0
|
下载量0
段落导航相关论文