小单元多丝漂移室探测器系统研制OACSTPCD
Development of Detector System with Small Cell Multi-wire Drift Chamber
为精确测量CSR外靶终端靶前入射粒子的径迹,研制了多套小单元多丝漂移室探测器,该探测器灵敏面积为80 mm×80 mm,每套探测器包括x、x'、v、y 4个探测电极面,每个电极面引出16个阳极丝信号.前端电子学采用基于SFE16芯片的放大器,数据读出系统采用基于HPTDC芯片的数据采集卡.采用两套小单元多丝漂移室对400 MeV/u的16 O束流位置进行了测试,探测器的工作气体为Ar(80%)+CO2(20%),阳极丝电压为+900 V,场丝与阴极丝均接地,拟合得到的单层电极的位置分辨(拟合残差)为105.9μm,探测效率为99.3%,该指标可以满足现阶段CSR外靶终端大部分核物理实验对反应靶点的定位要求.
In order to accurately measure the path of the incident particles in front of the target at the CSR outer target terminal,multiple sets of small cell multi-wire drift chamber detectors were developed with a drift cell of 5 mm.The sensitive area of this detector is 80 mm×80 mm,each set of detector includes x,x',y and y'4 detection electrode surfaces,2 sets of detection electrode surface wires are perpendicular to each other,and the same direction detection electrode surface wires are misaligned and distributed for providing left and right resolution,the misalignment distance of 2.5 mm for half drift cell,each electrode surface leads to 16 anode wire signals.The front-end electronics uses an amplifier based on the SFE16 chip,a 16-way ASIC signal processing developed by Saclay,France,whose functions include charge-sensitive amplification,shaping and signal screening,and outputting the TOT signal.The TOT signal is input to a data acquisition card based on the HPTDC chip developed by CERN,which records the rising and falling edge times of the TOT signal.The T0 plastic flash detector,placed in front of the drift chamber,provides the onset moment of the incident particles.By subtracting the TOT signal front from T0,the drift time of the incident particle traces in the multi-wire drift chamber can be obtained.The particles incident to the secondary target are physically concerned as heavy particles,so 2 sets of small cell multi-wire drift chambers were used to test the 16 O beam position at 400 MeV/u.During the test,the operating gas of the detector was Ar(80%)+CO2(20%),the anode wire voltage was+900 V,and both the field and cathode wires were grounded.After acquiring the test data for data processing,the R-T curves were obtained by simulation with interpolation correction,and the path traces were reconstructed by least squares method.After the data processing,the path residual of the single-layer electrode fitted to obtain the position resolution is 105.9 μm,and the path residual is defined as the difference between the distance from each hitting wire to the fitted straight line and the drift distance measured in each layer.The detection efficiency is 99.3%,and the detection efficiency is defined as the ratio of the count of the multi-wire drift chamber to the count of the plastic flash detector after deducting the background.The above indexes can meet the requirements of most of the nuclear physics experiments of the CSR external target terminal for the localization of the reaction target at this stage.
黄鑫杰;秦雨浩;魏向伦;杨贺润;鲁辰桂;李蒙;杨远胜;李志杰;段利敏;尹小豪;何周波;马朋;胡荣江;邹海川;邱天力;何志轩;秦智
中国科学院近代物理研究所,甘肃兰州 730000||中国科学院大学核科学与技术学院,北京 100049清华大学物理系,北京 100084兰州大学核科学与技术学院,甘肃兰州 730000
核科学
小单元多丝漂移室位置分辨探测效率
small cellmulti-wire drift chamberposition resolutiondetection efficiency
《原子能科学技术》 2024 (001)
利用GEM读出的时间投影室对快中子诱发裂变产物多参数测量的研究
218-224 / 7
中国科学院战略重点研究项目(XDB34000000);国家重点研发计划(2018YFE0205200);国家重大科研仪器研制项目(11927901);国家自然科学基金(11875301,11875302,U1867214,U1832105,U1832167);中国科学院功能开发项目(2022G101)
评论