常规超声和超声造影在犬脾脏超声消融效果评估中的价值
Value Comparison of Conventional Ultrasound and Contrast-Enhanced Ultrasound in Evaluation of Ultrasonic Ablation Effect of Canine Spleen
蔡洁璇 1陈义洲 2孙梦迪 3刘伟 4谢浩铭 1张旭銮 1万绍兵 1戴灵苓 1李河谕 1石达友2
作者信息
- 1. 华南农业大学兽医学院,广东广州 510642
- 2. 华南农业大学兽医学院,广东广州 510642||广东省兽医临床重大疾病综合防控重点实验室,广东广州 510642
- 3. 深圳市普罗医学股份有限公司,广东深圳 518000
- 4. 深圳迈瑞动物医疗科技股份有限公司,广东深圳 518110
- 折叠
摘要
Abstract
To compare the value of conventional ultrasound and contrast-enhanced ultrasound(CEUS)in the assessment of high-intensity focused ultrasound(HIFU)ablation effects on the normal canine spleen,six healthy adult Chinese indigenous dogs underwent extracorporeal spleen HIFU ablation.Conventional ultrasound and CEUS were performed immediately post-ablation(Day 0)and on Days 3,7,14,21,and 28 to evaluate the size,morphology,echogenicity changes,and boundaries of the ablation zone,measuring the left-right and maximum cranio-caudal diameters.The results showed that in conventional ultrasound mode,the ablation zone exhibited a mixed echogenicity structure of high,iso,and low echogenicity with a relatively unclear boundary compared to normal tissue.In CEUS mode,the ablation zone appeared as a uniformly hypoechoic structure with a clear boundary.Median measurements of the left-right diameter in CEUS were significantly larger than in conventional ultrasound at both immediate and Day 3 post-ablation,with statistical significance(P<0.05).However,on Day 7,14,21,and 28 post-ablation,there was no statistically significant difference in measurements between the two methods(P>0.05).Measurements of the maximum cranio-caudal diameter in both methods on Day 3 were significantly larger than immediate post-ablation,with statistical significance(P<0.05).Subsequently,the maximum cranio-caudal diameter showed a trend of continuous reduction compared to immediate post-ablation.The results indicate that in the assessment of canine spleen HIFU ablation effects and dynamic monitoring of changes in the ablation zone post-treatment,CEUS is more sensitive and accurate in displaying the location and extent of the ablation zone than conventional ultrasound.However,for simplifying the examination process and reducing costs,conventional ultrasound can also be used for postoperative dynamic monitoring of the ablation zone.关键词
犬/高强度聚焦超声消融/常规超声/超声造影/脾脏Key words
dog/high-intensity focused ultrasound ablation/conventional ultrasound/contrast-enhanced ultrasound/spleen分类
农业科技引用本文复制引用
蔡洁璇,陈义洲,孙梦迪,刘伟,谢浩铭,张旭銮,万绍兵,戴灵苓,李河谕,石达友..常规超声和超声造影在犬脾脏超声消融效果评估中的价值[J].中国兽医杂志,2023,59(12):117-121,5.