首页|期刊导航|电网技术|计及电能质量影响的主动配电网光储容量优化

计及电能质量影响的主动配电网光储容量优化OA北大核心CSTPCD

Optimal Capacity Configuration of Photovoltaic and Energy Storage System in Active Distribution Network Considering Influence of Power Quality

中文摘要英文摘要

"双碳"目标的提出,配电网新能源接入已成必然,光储并网配置将成为影响配电网电能质量的关键因素之一.该文建立一种计及电能质量影响的主动配电网光储双层优化配置模型,下层调度模型采用基于二阶锥规划的最优潮流模型,以系统网损最低为目标对各主动管理措施和分布式电源出力进行调度;上层配置模型以发电系统年投资运行成本、各光伏并网点电能质量评估值、系统总弃光率和储能收益为目标进行优化,采用向量序优化理论进行求解,保证计算结果的快速性和准确性.采用IEEE-33节…查看全部>>

The pursuit of"double carbon"goals has made it imperative to integrate new sources of energy into distribution networks.In this context,the grid-connected configuration of optical storage is emerging as a crucial factor that affects the power quality of such networks.This paper establishes a double-layer optimal allocation model of photovoltaic and energy storage systems in the active distribution network considering the influence of power quality.The lower-…查看全部>>

王子辉;贾燕冰;李彦晨;韩肖清

电力系统运行与控制山西省重点实验室(太原理工大学),山西省 太原市 030024电力系统运行与控制山西省重点实验室(太原理工大学),山西省 太原市 030024国网山西省电力公司临汾供电公司,山西省 临汾市 041000电力系统运行与控制山西省重点实验室(太原理工大学),山西省 太原市 030024

动力与电气工程

配电网电能质量综合评估光储系统双层优化配置

distribution networkpower qualitycomprehensive evaluationphotovoltaic and energy storage systemdouble-layer optimal configuration

《电网技术》 2024 (2)

607-617,中插26-中插28,14

国家自然科学基金联合基金重点项目(U1910216).Project Supported by National Natural Science Foundation of China Joint Fund Key Project(U1910216).

10.13335/j.1000-3673.pst.2023.0076

评论