Abstract

The current national standard GB 8368-2018 has the microscopic counting method as the only detailed test method of the liquid filtration rate of liquor filter,which has complex and inefficient operation,but the particle counter method mentioned in in this standard has no specific operation method.In this paper,the particle counter method is explored and studied,and the results are verified by the microscopic counting method.Results show that the particle counter method is simple and accurate,which can greatly improve work efficiency,compared with the microscopic counting method.

关键词

微粒计数器/输液器药液过滤器/滤除率/测试方法

Key words

particle counter/liquor filter/filtration rate/test method