摘要

Abstract

The high-voltage transformer-less battery energy storage system(BESS)adopts the concept of cascading H-bridge circuits to connect the high voltage power grid.A large number of battery cells are separated equally into numerous clusters at the DC side of H-bridge submodules,and a high degree of modularity features the BESS.Compared with the low-voltage solution,it has obvious advantages such as larger capacity of single-machine,higher efficiency,and faster response speed.If the high-voltage transformer-less BESS also has reactive power compensation capabilities and can realize the four-quadrant operation of the system,greater cost advantages and economic benefits will be obtained.When the system operates at a high proportion of reactive power compensation,the structure of the battery cluster connected to the single-phase H-bridge converter results in that the battery current will reverse in a cycle of twice the fundamental frequency.The battery is charged and discharged with high frequency,which will have a great impact on battery life and battery status monitoring.To solve this problem,this paper proposes a high-proportion reactive power compensation control based on zero-sequence voltage injection and the charged and discharged current with twice the fundamental frequency is removed.Besides,the amplitude and phase of the zero-sequence voltage are optimized to minimize the impact on the battery.

关键词

高压直挂/电池储能/无功补偿/零序电压/功率因素/四象限

Key words

high-voltage transformer-less/battery energy/reactive power compensation/zero-sequence voltage/power factor/four quadrants