| 注册
首页|期刊导航|中国中西医结合杂志|围术期电针对肺切除术后心律失常影响随机对照研究

围术期电针对肺切除术后心律失常影响随机对照研究

周正清 张永燕 高静雅

中国中西医结合杂志2024,Vol.44Issue(2):143-148,6.
中国中西医结合杂志2024,Vol.44Issue(2):143-148,6.DOI:10.7661/j.cjim.20231009.248

围术期电针对肺切除术后心律失常影响随机对照研究

Effectiveness of Perioperative Electrotherapy on Arrhythmia After Pneumonectomy:A Randomized Controlled Trial

周正清 1张永燕 1高静雅1

作者信息

  • 1. 上海中医药大学附属岳阳中西医结合医院麻醉科(上海 200437)
  • 折叠

摘要

Abstract

Objective To study the effect of perioperative electroacupuncture(EA)intervention on arrhythmia after pneumonectomy and the influence of risk on new-onset arrhythmia.Methods A total of 314 lung cancer patients who received pneumonectomy from Jan,2020 to Oct,2022 were included,and they were assigned to the control group(157 cases)and EA group(157 cases)according to the random number table.Patients in the control group received conventional perioperative treatment,while those in the EA group received EA at Neiguan(PC6),Waiguan(SJ5),Xinshu(BL15),Shenmen(HT7),Tongli(HT5),Chize(LU5)and Hegu(LI4)combined with conventional treatment.The occurrence of arrhythmia in the 2 groups were compared.The serum level of interleukin-6(IL-6),tumor necrosis factor-α(TNF-α),hypersensitive C-reactive protein(hs-CPR),NT-pro brain natriuretic peptide(NT-proBNP)were detected.Visual analogue scale(VAS)was used to assess pain score.Multivariate Logistic regression was used to analyze the effect of high-risk factors of EA for arrhythmia after pneumonectomy during the perioperative period.Results Compared with before surgery,IL-6,TNF-α,hs-CPR,NT-proBNP and VAS pain score in the 2 groups decreased when awake from anesthesia(P<0.01).Compared with the control group,the incidence of ventricular and atrial premature beats,and the total incidence of arrhythmia decreased in EA group(P<0.05,P<0.01),IL-6,TNF-α,hs-CPR,NT-proBNP and VAS pain score decreased in EA group when awake from anesthesia(P<0.01),and the difference value of IL-6,TNF-α,hs-CPR,NT-proBNP and VAS pain score between before and after operation increased in EA group(P<0.01).Multivariate Logistic regression analysis showed that the increasing of IL-6[OR=2.030,95%CI(1.250,3.297)],TNF-α[OR=3.147,95%CI(1.391,7.118)],hs-CPR[OR=1.972,95%CI(1.078,3.609)]and NT-proBNP[OR=1.683,95%CI(1.013,2.796)]when awake from anesthesia were risk factors for arrhythmia after pneumonectomy.The elevated differential values of TNF-α[OR=0.089,95%CI(0.011,0.741)]and hs-CPR[OR=0.242,95%CI(0.084,0.695)]were protective factors for arrhythmias after pneumonectomy.Conclusions Perioperative EA therapy can effectively reduce the incidence of arrhythmia and provide a new strategy for the prevention of arrhythmia after pneumonectomy.(Chinese Clinical Trial Registry,No.ChiCTR2100047499).

关键词

肺癌/肺切除术/围术期/针刺疗法/心律失常/中西医结合/随机对照试验

Key words

lung cancer/pneumonectomy/perioperative period/acupuncture therapy/arrhythmia/integrative medicine/randomized controlled trial

引用本文复制引用

周正清,张永燕,高静雅..围术期电针对肺切除术后心律失常影响随机对照研究[J].中国中西医结合杂志,2024,44(2):143-148,6.

基金项目

上海市卫生健康委员会科研课题计划任务(No.202040310) (No.202040310)

中国中西医结合杂志

OA北大核心CSTPCD

1003-5370

访问量6
|
下载量0
段落导航相关论文