| 注册
首页|期刊导航|理化检验-物理分册|电厂锅炉再热器管开裂原因

电厂锅炉再热器管开裂原因

刘永超

理化检验-物理分册2024,Vol.60Issue(2):28-30,3.
理化检验-物理分册2024,Vol.60Issue(2):28-30,3.DOI:10.11973/lhjy-wl202402008

电厂锅炉再热器管开裂原因

Causes of reheater tube cracking in power plant boiler

刘永超1

作者信息

  • 1. 中国大唐集团科学技术研究总院有限公司 大唐华北电力试验研究院, 北京 100040
  • 折叠

摘要

Abstract

Steam leakage accidents occurred in the front wall reheater tube,water wall tube and partition screen tube of a power plant boiler.The causes of boiler tube cracking were analyzed by means of macroscopic observation,metallographic examination and hardness test.The results show that the cracking point of the boiler tube was located on the wall reheater tube.The cracking reason was not the overheating of the tube or its own defects,but the wrong welding between the sliding plate and the front side of the 31 wall reheater tubes near the furnace during the installation and construction process,resulting in defects and cracking of the tube.

关键词

锅炉壁再热器管/开裂/显微组织/残余应力

Key words

boiler wall reheater tube/cracking/microstructure/residual stress

分类

通用工业技术

引用本文复制引用

刘永超..电厂锅炉再热器管开裂原因[J].理化检验-物理分册,2024,60(2):28-30,3.

理化检验-物理分册

1001-4012

访问量0
|
下载量0
段落导航相关论文