摘要
Abstract
Taking the cross-flow flat membrane dehumidification module as the research object,the effects of inlet humid air velocity,inlet humid air tem-perature,inlet humid air moisture content,inlet dehu-midification solution velocity,inlet dehumidification so-lution temperature,inlet dehumidification solution mass fraction and other factors on the dehumidification per-formance of membrane module are experimentally ana-lyzed.Reducing the inlet humid air velocity can im-prove the dehumidification performance of the module.Compared with the inlet humid air velocity,the inlet humid air temperature and inlet humid air moisture content have less influence on the dehumidification performance of the membrane module.Increasing the inlet dehumidification solution velocity can improve the dehumidification performance of the membrane mod-ule.Compared with the inlet dehumidification solution velocity,the inlet dehumidification solution temperature and inlet dehumidification solution mass fraction have less influence on the dehumidification performance of the membrane module.关键词
膜除湿/错流式平板膜组件/除湿性能Key words
membrane dehumidification/cross-flow flat membrane module/dehumidification perform-ance分类
建筑与水利引用本文复制引用
牛润萍,李翼帆,孔祥辰..错流式平板膜除湿组件除湿性能实验研究[J].煤气与热力,2024,44(3):17-22,6.基金项目
国家自然科学基金面上项目(52078022) (52078022)