本文研究设计的输电线路钢管杆塔沉降监测系统,依托单杆塔目标灾害预测、区域内杆塔整体风险预测等安全物联网领域核心技术,为电力输电线路钢管杆塔沉降打造安全物联网支撑平台,提供整体解决方案及全生命周期的系统服务.系统基于北斗卫星导航系统(BeiDou Satellite Navigation System,BDS)及倾斜监测预警技术,以输出BDS的原始数据为核心,包括载波相位观测数据、星历数据等,并通过4G无线网络传到控制中心,控制中心通过监测软件实时解算出各监测点的三维坐标,然后根据对实时位移数据的对比分析,形成不同的监测系统或环境下的实时差异数据,再根据差异补正电力杆塔沉降区域变形情况和详细数据.

This article introduces a monitoring system for transmission line steel pipe rod settlement monitoring system.The system relies on core technologies in the field of secure IoT,such as single-tower target disaster prediction and overall risk prediction of towers in the region,to create a secure IoT support platform for the subsidence of steel pipe towers in power transmission lines,providing overall solutions and system services throughout the life cycle.The system is based on the BeiDou Satellite Navigation System(BDS)and tilt monitoring and warning technology,with the output of the BDS's raw data,including carrier phase observation data,ephemeris data,etc.,as the core.The data is transmitted to the control center via 4G wireless network.The control center calculates the three-dimensional coordinates of each monitoring point in real-time through monitoring software,and then forms real-time differential data under different monitoring systems or environments according to the comparative analysis of real-time displacement data.Finally,the deformation of the subsidence area of the power tower is corrected according to the differential data and detailed data.This system can effectively prevent various accidents caused by tower inclination and improve the safety operation level of the power grid.

金福铭;段意;刘智慧;张鹏;栾俊清

内蒙古电力(集团)有限责任公司包头供电分公司,内蒙古自治区包头市 014000

测绘与仪器

输电线路钢管杆沉降监测系统北斗卫星导航系统(BDS)载波相位数据星历

transmission line steel pipe rod settlement monitoring systemBeiDou Satellite Navigation System(BDS)carrier phase dataephemeris

《全球定位系统》 2024 (001)

54-59 / 6

内蒙古电力(集团)有限责任公司科技项目资助(内电科信[2021]3号)

10.12265/j.gnss.2023185