| 注册
首页|期刊导航|锅炉技术|W型火焰锅炉炉内气流组织优化及模拟研究

W型火焰锅炉炉内气流组织优化及模拟研究

申加旭 赛俊聪 李恒阳 秦欢

锅炉技术2024,Vol.55Issue(2):27-31,5.
锅炉技术2024,Vol.55Issue(2):27-31,5.

W型火焰锅炉炉内气流组织优化及模拟研究

Optimization and Simulation Study on Air Flow in W-Shaped Flame Boiler Furnace

申加旭 1赛俊聪 1李恒阳 1秦欢1

作者信息

  • 1. 云南电力试验研究院(集团)有限公司,云南 昆明 650217
  • 折叠

摘要

Abstract

In this paper,the numerical model of W-shaped flame boiler was established by using CFD to study the changes of air flow in the furnace,the fly ash erosion and of furnace wall wear before and after the cold air-dynamic test.The results show that a good W-shape can be obtained by optimizing the air flow in the cold air-dynamic test;After leveling,the flow field inside the furnace was optimized,the overall wear was improved and the wear rate was reduced from 4×10-6 kg/(m2·s)to 1.5×10-6 kg/(m2·s);The reasonable air flow structure has a great influence on the wear of furnace wall.The maximum fluctuation range before leveling was 25×10-7kg/(m2·s),and the one after leveling was 5×10-7 kg/(m2·s).The reasonable air distribution was an important factor to ensure the decrease of furnace wall wear.

关键词

W型火焰锅炉/冷态试验/空气动力场/磨损速率

Key words

W-shaped flame boiler/cold air-dynamic test/aerodynamic field/wear rate

分类

能源科技

引用本文复制引用

申加旭,赛俊聪,李恒阳,秦欢..W型火焰锅炉炉内气流组织优化及模拟研究[J].锅炉技术,2024,55(2):27-31,5.

锅炉技术

OA北大核心

1672-4763

访问量0
|
下载量0
段落导航相关论文