| 注册
首页|期刊导航|锅炉技术|HBS-LNSB Ⅲ型旋流燃烧器回流区和着火距离的试验研究

HBS-LNSB Ⅲ型旋流燃烧器回流区和着火距离的试验研究

葛铭 黄继忠 张苗 严晓勇 刘晓东 陈晓龙 胡珺 张永 田绍钢 骆宏飞 蒋峰

锅炉技术2024,Vol.55Issue(2):45-52,8.
锅炉技术2024,Vol.55Issue(2):45-52,8.

HBS-LNSB Ⅲ型旋流燃烧器回流区和着火距离的试验研究

Experimental Study on Recirculation Zone and Ignition Standoff Distance of HBS-LNSB Ⅲ Swirl Burner

葛铭 1黄继忠 2张苗 2严晓勇 3刘晓东 1陈晓龙 1胡珺 4张永 4田绍钢 4骆宏飞 4蒋峰3

作者信息

  • 1. 国家能源集团科学技术研究院有限公司,江苏 南京 210023
  • 2. 国能九江发电有限公司,江西 九江 332000
  • 3. 国能福州热电有限公司,福建 福州 350309
  • 4. 国能蚌埠发电有限公司,安徽 蚌埠 233412
  • 折叠

摘要

Abstract

The experimental investigation of recirculation zone and ignition characteristics on a swirl burner were studied.The effects of central air quantity,external secondary air quanti-ty,internal secondary air quantity and swirl intensity of internal secondary air on the size of recirculation zone were investigated.It was found that the change of internal secondary air quantity had the greatest influence on the width of recirculation zone while the change of cen-tral air quantity had the greatest influence on the distance between the recirculation zone and burner.The experimentation results provided a basis for the selection of air distribution for coal combustion with different combustion characteristics.The ignition standoff distance of pulverized coal under various influencing factors was studied.It was found that the ignition standoff distance of free-burning coal is short.In order to avoid burner port burning,the most effective measures are increasing the central air quantity and primary air velocity.Due to the low temperature of furnace,the ignition standoff distance of pulverized coal become longer and the blending ratio of free-burning coal can be increased at low load.For the coal with high ignition temperature,the changes of central air quantity,external secondary air quantity and internal secondary air quantity have obvious regular effects on ignition standoff distance.The influence of swirl intensity of internal secondary air must comprehensively con-sider the influence of air quantity change caused by swirl intensity.The industrial tests of dif-ferent coal ignition standoff distance provide guidance for the selection of burner air distribu-tion.Industrial test on ignition distance and recirculation zone should be carried out when the coal types change greatly in order to find the best choice for burner air distribution.

关键词

旋流燃烧器/回流区/着火距离/旋流强度/中心风

Key words

swirl burner/recirculation zone/ignition standoff distance/swirl intensity/central air

分类

能源科技

引用本文复制引用

葛铭,黄继忠,张苗,严晓勇,刘晓东,陈晓龙,胡珺,张永,田绍钢,骆宏飞,蒋峰..HBS-LNSB Ⅲ型旋流燃烧器回流区和着火距离的试验研究[J].锅炉技术,2024,55(2):45-52,8.

基金项目

国家能源集团科技项目(GJNY-20-10-3) (GJNY-20-10-3)

锅炉技术

OA北大核心

1672-4763

访问量0
|
下载量0
段落导航相关论文