锅炉技术2024,Vol.55Issue(2):60-67,8.
350MW超临界循环流化床锅炉天然气点火系统调试实践
Commissioning Practice of Natural Gas Ignition System for 350 MW Supercritical Circulating Fluidized Bed Boiler
摘要
Abstract
In view of the problems existing in the commissioning process of the natural gas ignition system of 350 MW supercritical Circulating Fluidized Bed(CFB)boiler,such as the under bed gas guns often fail to ignite,the flames blown off after ignition,the on bed ignition gas guns are hard to ignite,and the main gas guns on the bed cannot be ignited and it extinguish fire after the bed ignition gas gun exits.Through a series of means such as equipment improvement,ignition parameters adjustment,and optimization of ignition program,the on-site problems are solved,and the natural gas ignition system meets the boiler startup requirements.关键词
超临界/循环流化床锅炉/天然气点火系统/灭火脱火/改进调整/稳定燃烧Key words
supercritical/CFB boiler/natural gas ignition system/blown off/improvement and adjustment/stable combustion分类
能源科技引用本文复制引用