Abstract
A cylindrical thermal storage water tank with orifice plates above and below is taken as the research object,and a thermal storage performance ex-perimental platform is constructed for the thermal stor-age water tank.Multiple operational conditions are de-signed,the thickness of the thermocline is used as the evaluation index to study the influence of pore plate water distribution structure parameters(hole area ratio and number of holes)on thermal storage performance.Placing orifice plates in the heat storage water tank can effectively prolong the duration of the thermocline dur-ing the heat storage process and reduce the thickness of the generated thermocline.For both single hole and porous hole plate schemes,the optimal ratio of opening area is 0.2.关键词
蓄热水罐/孔板/布水结构/相似模化/斜温层Key words
thermal storage tank/orifice plate/water distribution structure/similarity modeling/ther-mocline分类
建筑与水利引用本文复制引用