| 注册
首页|期刊导航|科技创新与应用|自易法测量矩形换能器超声功率研究

自易法测量矩形换能器超声功率研究

宋仁杰 王亮 宋丹 罗曼 周小伟

科技创新与应用2024,Vol.14Issue(11):57-63,7.
科技创新与应用2024,Vol.14Issue(11):57-63,7.DOI:10.19981/j.CN23-1581/G3.2024.11.014

自易法测量矩形换能器超声功率研究

宋仁杰 1王亮 1宋丹 1罗曼 2周小伟3

作者信息

  • 1. 重庆医科大学 生物医学工程学院 超声医学工程国家重点实验室,重庆 400016
  • 2. 重庆医科大学 生物医学工程学院 超声医学工程国家重点实验室,重庆 400016||超声医疗国家工程研究中心,重庆 401121||国家药品监督管理局超声手术设备质量评价重点实验室,武汉 430075
  • 3. 重庆医科大学 生物医学工程学院 超声医学工程国家重点实验室,重庆 400016||超声医疗国家工程研究中心,重庆 401121
  • 折叠

摘要

Abstract

A method for measuring the ultrasonic power of a rectangular transducer accurately and quickly based on self-re-ciprocity technique was explored.Firstly,the electroacoustic reciprocity principle in the self-reciprocity calibration method was used to analyze the relationship between the open-circuit voltage,the first echo current and the ultrasonic power,the expression for the calculation of the rectangular transducer ultrasonic power was derived based on self-reciprocity measurement,and the calculation method of diffraction coefficient was discussed.Then,the ultrasonic power of two rectangular transducers with different aspect ratios were measured under different excitation voltages using self-reciprocity method and radiation force balance method.The results ob-tained by the two methods were linearly fitted with the electric power and the square of effective value of driving voltage,respec-tively.The results indicated that the measurement consistency of the two methods was good,which showed the effectiveness of self-reciprocity method for the measurement of rectangular transducer ultrasonic power.Finally,the applicable scope of the method was discussed.

关键词

矩形换能器/自易法/衍射系数/辐射力天平/超声功率测量

Key words

rectangular transducer/self-reciprocity method/diffraction coefficient/Radiation Force Balance/ultrasonic power measurement

分类

通用工业技术

引用本文复制引用

宋仁杰,王亮,宋丹,罗曼,周小伟..自易法测量矩形换能器超声功率研究[J].科技创新与应用,2024,14(11):57-63,7.

基金项目

国家自然科学基金青年科学基金项目(12304508) (12304508)

科技创新与应用

2095-2945

访问量0
|
下载量0
段落导航相关论文