| 注册
首页|期刊导航|医疗卫生装备|不同型号血细胞分离机行血浆置换治疗的差异比较

不同型号血细胞分离机行血浆置换治疗的差异比较

王文婷 郑妍 任冬霞 王晓清 王林

医疗卫生装备2023,Vol.44Issue(10):55-58,4.
医疗卫生装备2023,Vol.44Issue(10):55-58,4.DOI:10.19745/j.1003-8868.2023207

不同型号血细胞分离机行血浆置换治疗的差异比较

Comparative analysis of therapeutic plasma exchange with different types of blood cell separators

王文婷 1郑妍 1任冬霞 1王晓清 1王林1

作者信息

  • 1. 空军军医大学唐都医院输血科,西安 710038
  • 折叠

摘要

Abstract

Objective To analyze and compare the therapeutic effects of COM.TEC and COBE Spectra blood cell separators in therapeutic plasma exchange.Methods Totally 20 patients admitted to some hospital from March to July 2022 were selected as the study subjects prospectively,and then divided into A and B groups randomly.Therapeutic plasma exchange was carried out with COM.TEC blood cell separator in group A(10 cases,42 treatments)and COBE Spectra blood cell separator in group B(10 cases,36 treatments).The two groups were compared in terms of anticoagulant dosage,plasma exchange time and adverse events.SPSS 25.0 software was used for statistical analysis.Results The anticoagulant dosage for per liter of circulating blood volume in group A was(76.83±7.80)mL,which was significantly lower than that((83.89±1.16)mL)in group B(t=5.040,P<0.05).When the fluid balance was set to 100%,the plasma exchange time for per liter of plasma in group A was(38.39±5.74)min,which was statistically shorter than that((42.30±5.35)min)in group B(t=3.528,P<0.05).There were 11 adverse events in group A including 2 allergic reactions and 9 instrument alarms,and 8 adverse events in group B including 4 allergic reactions and 4 instrument alarms.Conclusion Both COM.TEC and COBE Spectra blood cell separators can meet the requirements for clinical treatment in spite of differences in performances,and the blood cell separator has to be selected properly for therapeutic plasma exchange based on patient conditions.[Chinese Medical Equipment Journal,2023,44(10):55-58]

关键词

血细胞分离机/血浆置换/置换液/抗凝剂

Key words

blood cell separator/plasma exchange/replacement fluids/anticoagulant

分类

医药卫生

引用本文复制引用

王文婷,郑妍,任冬霞,王晓清,王林..不同型号血细胞分离机行血浆置换治疗的差异比较[J].医疗卫生装备,2023,44(10):55-58,4.

基金项目

军委后勤保障部卫生局卫勤保障能力创新与生成专项项目(21WQ28) (21WQ28)

空军军医大学唐都医院科技创新项目(2019LCYJ017) (2019LCYJ017)