| 注册
首页|期刊导航|云南水力发电|土坝溢洪道底流消能计算成果分析

土坝溢洪道底流消能计算成果分析

陈嘉颖

云南水力发电2024,Vol.40Issue(4):86-89,4.
云南水力发电2024,Vol.40Issue(4):86-89,4.DOI:10.3969/j.issn.1006-3951.2024.04.021

土坝溢洪道底流消能计算成果分析

Analysis of Calculation Results of Bottom Flow Energy Dissipation in Earth Dam Spillway

陈嘉颖1

作者信息

  • 1. 广东省水利水电科学研究院,广东 广州 510000
  • 折叠

摘要

Abstract

This paper analyzes the calculation process and results of the bottom flow energy dissipation of a certain reservoir of Foshan in 2019 and 2020.It adopts two methods,namely spillway design specifications and hydraulic calculation manuals,to review the energy dissipation and erosion prevention of the same project,and to identify the differences and reasons in the calculation results.In order to reduce the economic cost of the reinforcement project for small and medium-sized reservoirs,combined with the current situation of the spillway of the reservoir,it is proposed that the calculation of the pre jump head of the energy dissipator should adopt the segmented sum method of the energy equation considering the head loss along the discharge path.This method is more suitable for actual working conditions and can reduce project implementation costs while ensuring safety.

关键词

底流消能/溢洪道/消能防冲/安全复核

Key words

underflow energy dissipation/spillway/energy dissipation and erosion prevention/safety check

分类

建筑与水利

引用本文复制引用

陈嘉颖..土坝溢洪道底流消能计算成果分析[J].云南水力发电,2024,40(4):86-89,4.

云南水力发电

1006-3951

访问量0
|
下载量0