| 注册
首页|期刊导航|河南理工大学学报(自然科学版)|不同桩长对GFRP复合桩竖向承载性能影响研究

不同桩长对GFRP复合桩竖向承载性能影响研究

边汉亮 马宇豪 张建伟 瑜璐 樊亚龙

河南理工大学学报(自然科学版)2024,Vol.43Issue(2):177-185,9.
河南理工大学学报(自然科学版)2024,Vol.43Issue(2):177-185,9.DOI:10.16186/j.cnki.1673-9787.2022120033

不同桩长对GFRP复合桩竖向承载性能影响研究

Effect of different pile sizes on vertical bearing capacity of GFRP composite piles

边汉亮 1马宇豪 1张建伟 1瑜璐 1樊亚龙2

作者信息

  • 1. 河南大学 土木建筑学院,河南 开封 475004
  • 2. 中建七局第四建筑有限公司,陕西 西安 710000
  • 折叠

摘要

Abstract

Objectives To explore the influence of pile length on the vertical bearing capacity of glass fiber reinforced composite piles(GFRP composite piles).Methods A series of model tests were performed to in-vestigate the vertical bearing capacity of ordinary reinforced concrete piles(RC pile)and GFRP composite piles,respectively.Simultaneously,the effect of pile length was analyzed through finite element analyses for the vertical bearing capacity.Results In the model tests,the vertical bearing capacity of GFRP composite piles was found to be greater than that of RC piles.When the pile top load is 6 kN,the lateral friction resis-tance of GFRP composite piles accounts for 34.1%of the pile top load,while RC piles account for 24.7%.GFRP material significantly changes the roughness of the pile body,enhances the interface friction charac-teristics of the pile body,and generates smaller end resistance under higher vertical loads.In finite element software simulation,compared with RC piles,the friction coefficient between GFRP fabric and soil is greater than that between concrete and soil,which is conducive to the development of lateral friction resis-tance of GFRP composite piles.The proportion of end resistance of GFRP composite piles with the same pile length is significantly lower than that of RC piles.Compared with RC piles with pile lengths of 5,10,and 15 meters,the lateral friction values of GFRP composite piles account for 35.69%,42.44%,and 50.54%of the ultimate bearing capacity of the pile.The lateral friction values of GFRP composite piles account for 42.44%,63.09%,and 75.69%of the ultimate bearing capacity of the pile,respectively.This indicates that GFRP composite piles improve their vertical bearing capacity by increasing lateral friction,and the longer the pile length,the more significant the improvement in the bearing performance of GFRP composite piles.Conclusions The vertical bearing capacity of GFRP composite piles with the same pile length is signifi-cantly higher than that of RC piles.With increasing length,the side friction of the GFRP composite pile in-creased,which led to the corresponding results:a higher ultimate bearing capacity in the pile foundation,and larger interface friction of GFRP composite pile-soil.The conclusions could provide some suggestions for the design of the vertical bearing capacity of GFRP composite piles..

关键词

GFRP复合桩/竖向承载性能/模型试验/压实度/摩擦系数

Key words

GFRP composite pile/vertical bearing capacity/model test/compaction degree/friction coefficient

分类

建筑与水利

引用本文复制引用

边汉亮,马宇豪,张建伟,瑜璐,樊亚龙..不同桩长对GFRP复合桩竖向承载性能影响研究[J].河南理工大学学报(自然科学版),2024,43(2):177-185,9.

基金项目

国家自然科学基金资助项目(51508163) (51508163)

河南省研究生教育改革与质量提升工程项目(YJS2021JD13) (YJS2021JD13)